1.???????應(yīng)用LGR二氧化碳同位素分析儀,通過(guò)測(cè)定腸易激綜合癥患者的呼出氣體中的13CO2和12CO2的同位素分子比率,可以對(duì)患者體內(nèi)小腸細(xì)菌過(guò)度生長(zhǎng)情況做出正確診斷 Diagnosis of small intestinal bacterial overgrowth in irritable bowel syndrome patients using high-precision stable?13CO2/12CO2?isotope ratios in exhaled breath Gourab D. Banik,a??Abhijit Maity,a??Suman Som,a??Chiranjit Ghosh,a??Sunil B. Daschakraborty,b??Sujit Chaudhuri,b??Shibendu Ghoshc?and???Manik Pradhan*ad? Show Affiliations J. Anal. At. Spectrom., 2014,29, 1918-1924 Hydrogen breath tests (HBT) are widely used for the diagnosis of small intestinal bacterial overgrowth (SIBO) in patients with irritable bowel syndrome (IBS). However, the conclusions drawn from these studies are highly controversial, and several discrepancies exist in the results. The aim of our study is to develop an alternative?13C-glucose breath test (13C-GBT) methodology by measuring high-precision?13CO2/12CO2?isotope ratios in exhaled breath to accurately diagnose SIBO using an optical cavity-enhanced CO2?isotope analyzer. In all, 118 diarrhea-predominant (IBS-D) patients diagnosed according to ROME III criteria underwent?13C-GBT and HBT following the ingestion of a test meal containing 50 mg?13C-enriched glucose with 50 g glucose. The excretion of?13CO2?enrichments and a cumulative percentage dose of?13C-recovered (c-PDR) significantly depleted (p?< 0.001) for the positive SIBO patients (n?= 25) compared to the patients with negative SIBO (n?= 53) as diagnosed by HBT. A cut-off value of 5.47‰ at 45 min was indicative of a positive SIBO syndrome. Subsequently, a portion of IBS-D individuals (n?= 20) whose HBTs were negative but?13C-GBTs were positive, suggesting HBT often fails to diagnose SIBO when the patients may have “non-hydrogen-producing” bacteria.?13C-GBT also correctly diagnosed SIBO in patients (n?= 20) within the “grey-zone” and during the preclinical phase of SIBO as opposed to HBT. The prevalence of SIBO with IBS-D in Indian population was estimated to be 45.7%. Our study demonstrates?13C-GBT, for the first time, as a clinically valid and sufficiently robust alternative diagnostic methodology for an accurate evaluation of SIBO in IBS-D patients and superior to HBT. ? 2.???????13C尿素呼氣試驗(yàn)排泄動(dòng)力學(xué):內(nèi)部產(chǎn)生和藥物恢復(fù)的CO2對(duì)幽門螺桿菌感染的診斷準(zhǔn)確性的影響 Excretion kinetics of?13C-urea breath test: influences of endogenous CO2?production and dose recovery on the diagnostic accuracy of?Helicobacter pylori?infection Analytical and Bioanalytical Chemistry, September 2014, Volume 406, Issue 22, pp 5405-5412
Abstract We report for the first time the excretion kinetics of the percentage dose of?13C recovered/h (13C-PDR %/h) and cumulative PDR, i.e. c-PDR (%) to accomplish the highest diagnostic accuracy of the?13C-urea breath test (13C-UBT) for the detection of?Helicobacter pylori?infection without any risk of diagnostic errors using an optical cavity-enhanced integrated cavity output spectroscopy (ICOS) method. An optimal diagnostic cut-off point for the presence of?H. pylori?infection was determined to be c-PDR (%)?=?1.47 % at 60 min, using the receiver operating characteristic curve (ROC) analysis to overcome the “grey zone” containing false-positive and false-negative results of the?13C-UBT. The present?13C-UBT exhibited 100 % diagnostic sensitivity (true-positive rate) and 100 % specificity (true-negative rate) with an accuracy of 100 % compared with invasive endoscopy and biopsy tests. Our c-PDR (%) methodology also manifested both diagnostic positive and negative predictive values of 100 %, demonstrating excellent diagnostic accuracy. We also observed that the effect of endogenous CO2?production related to basal metabolic rates in individuals was statistically insignificant (p?=?0.78) on the diagnostic accuracy. However, the presence of?H. pylori?infection was indicated by the profound effect of urea hydrolysis rate (UHR). Our findings suggest that the current c-PDR (%) is a valid and sufficiently robust novel approach for an accurate, specific, fast and noninvasive diagnosis of?H. pylori?infection, which could routinely be used for large-scale screening purposes and diagnostic assessment, i.e. for early detection and follow-up of patients. Figure The excretion kinetics of the?13C-urea breath test with an ICOS system is demonstrated for accurate, specific, fast and noninvasive diagnosis of?H. pylori?infection in the human stomach? |